Expand Industrial Wireless I/O Capacity With A16000

industrial wireless communications equipment
The A16000 increases the I/O capacity of a dedicated
transmitter and receiver.
Modern industrial radio frequency (RF) communications gear enables the establishment of process signal connections across very small or very large distances. The advantages of implementing cost effective connections within a very short time frame makes wireless connections a popular option in industrial settings. A misconception arises, from time to time, that it is necessary to have a dedicated transmitter and receiver for each process signal. Analynk has a solution that provides for delivery of up to sixteen process signals over a single transmission path.

Analynk provides hardware that easily allows the transmission and reception of up to 16 I/O points using single transmission and reception point devices. The A16000 Expansion Module can be configured with up to four internal cards that accommodate various types of input and output signals. The configuration process is similar to setting up the I/O on a PLC. Connect the process signals to the A16000, and the A16000 to one of Analynk's transmitter or receiver devices. Setup is straight forward and allows the installation to be operable in a very short time frame. The A16000 can also be used to expand existing installations as process I/O points increase.

Share your wireless communications and signal transmission challenges with the experts at Analynk and get recommendations on how to best implement workable solutions.



Integrating Products Into a Complete Solution

explosion proof temperature transmitter
Explosion proof temperature transmitter, one of many
Telmar process measurement products.
Analynk Wireless manufactures equipment and crafts solutions for establishing wireless connections between process measurement and control locations, across the room, across the property, around the globe. As part of the company's product matrix, their Telmar branded products provide measurement points for complete application solutions. A review of the Telmar products.
  • Pressure to current transmitters
  • Current to pressure transmitters
  • Pressure to voltage or current
  • Current or voltage to pressure
  • Voltage to current
  • Current to voltage
  • RTD
  • Thermocouple
  • Slidewire
  • Tachometer
  • Power supplies
  • LCD digital meters
  • LED Indicators
  • Signal alarms
The Analynk application team can design and fabricate a complete package solution for your process measurement or wireless connectivity requirement. Share your ideas and challenges with the wireless and process measurement experts, leveraging your own knowledge and experience for an effective project outcome.

One Transmitter, One Receiver, Multiple Process Signals

Multiple input output module connects to single receiver or transmitter
A16000 Multiple I/O Module
Analynk
Radio frequency (RF) communications can enable the establishment or cost effective, quick, process signal connections across very small or very large distances. A misconception arises, from time to time, that it is necessary to have a dedicated transmitter and receiver for each process signal. Analynk has a solution that provides for delivery of up to sixteen process signals over a single transmission path.

Wireless transmission of process control signals is steadily increasing in prevalence throughout commercial, institutional and industrial settings. The ease of implementation, with no long cable runs to plan, layout, install, protect, and maintain, allows wireless installations to fulfill application niches that may have been considered impractical in the past.

Analynk provides hardware that easily allows the transmission and reception of up to 16 I/O points using a single transmitter and receiver. The A16000 Expansion Module can be configured with up to four internal cards that accommodate various types of input and output signals. The process is similar to setting up the I/O on a PLC. Connect the process signals to the A16000, and the A16000 to one of Analynk's transmitter or receiver devices. Setup is straight forward and allows the installation to be operable in minimal time.

Share your wireless communications and signal transmission challenges with the experts at Analynk and get recommendations on how to best implement workable solutions.


Attaining Close Temperature Control of Flowing Process Liquids

explosion proof temperature transmitter
Selection and placement of temperature sensors is a
critical element of achieving close temperature control.
Temperature control is a common operation in the industrial arena. Its application can range across solids, liquids, and gases. The dynamics of a particular operation will influence the selection of instruments and equipment to meet the project requirements. In addition to general performance requirements, safety should always be a consideration in the design of a temperature control system involving enough energy to damage the system or create a hazardous condition.

Let's narrow the application range to non-flammable flowing fluids that require elevated temperatures. In the interest of clarity, this illustration is presented without any complicating factors that may be encountered in actual practice. Much of what is presented here, however, will apply universally to other scenarios.
What are the considerations for specifying the right equipment?

KNOW YOUR FLOW


First and foremost, you must have complete understanding of certain characteristics of the fluid.
  • Specific Heat - The amount of heat input required to increase the temperature of a mass unit of the media by one degree.
  • Minimum Inlet Temperature - The lowest media temperature entering the process and requiring heating to a setpoint. Use the worst (coldest) case anticipated.
  • Mass Flow Rate - An element in the calculation for total heat requirement. If the flow rate will vary, use the maximum anticipated flow.Maximum Required Outlet Temperature - Used with minimum inlet temperature in the calculation of the maximum heat input required.


MATCH SYSTEM COMPONENT PERFORMANCE WITH APPLICATION


Heat Source - If temperature control with little deviation from a setpoint is your goal, electric heat will likely be your heating source of choice. It responds quickly to changes in a control signal and the output can be adjusted in very small increments to achieve a close balance between process heat requirement and actual heat input.

Sensor - Sensor selection is critical to attaining close temperature control. There are many factors to consider, well beyond the scope of this article, but the ability of the sensor to rapidly detect small changes in media temperature is a key element of a successful project. Attention should be given to the sensor containment, or sheath, the mass of the materials surrounding the sensor that are part of the assembly, along with the accuracy of the sensor.

Sensor Location - The location of the temperature sensor will be a key factor in control system performance. The sensing element should be placed where it will be exposed to the genuine process condition, avoiding effects of recently heated fluid that may have not completely mixed with the balance of the media. Locate too close to the heater and there may be anomalies caused by the heater. A sensor installed too distant from the heater may respond too slowly. Remember that the heating assembly, in whatever form it may take, is a source of disturbance to the process. It is important to detect the impact of the disturbance as early and accurately as possible.

Controller - The controller should provide an output that is compatible with the heater power controller and have the capability to provide a continuously varying signal or one that can be very rapidly cycled. There are many other features that can be incorporated into the controller for alarms, display, and other useful functions. These have little bearing on the actual control of the process, but can provide useful information to the operator.

Power Controller - A great advantage of electric heaters is their compatibility with very rapid cycling or other adjustments to their input power. A power controller that varies the total power to the heater in very small increments will allow for fine tuning the heat input to the process.

Performance Monitoring - Depending upon the critical nature of the heating activity to overall process performance, it may be useful to monitor not only the media temperature, but aspects of heater or controller performance that indicate the devices are working. Knowing something is not working sooner, rather than later, is generally beneficial. Controllers usually have some sort of sensor failure notification built in. Heater operation can be monitored my measurement of the circuit current.

SAFETY CONSIDERATIONS


Any industrial heater assembly is capable of producing surface temperatures hot enough to cause trouble. Monitoring process and heater performance and operation, providing backup safety controls, is necessary to reduce the probability of damage or catastrophe.

High Fluid Temperature - An independent sensor can monitor process fluid temperature, with instrumentation providing an alert and limit controllers taking action if unexpected limits are reached.

Heater Temperature - Monitoring the heater sheath temperature can provide warning of a number of failure conditions, such as low fluid flow, no fluid present, or power controller failure. A proper response activity should be automatically executed when unsafe or unanticipated conditions occur.

Media Present - There are a number of ways to directly or indirectly determine whether media is present. The media, whether gaseous or liquid, is necessary to maintain an operational connection between the heater assembly and the sensor.

Flow Present - Whether gaseous or liquid media, flow is necessary to keep most industrial heaters from burning out. Understand the limitations and operating requirements of the heating assembly employed and make sure those conditions are maintained.

Heater Immersion - Heaters intended for immersion in liquid may have watt density ratings that will produce excessive or damaging element temperatures if operated in air. Strategic location of a temperature sensor may be sufficient to detect whether a portion of the heater assembly is operating in air. An automatic protective response should be provided in the control scheme for this condition.

Each of the items mentioned above is due careful consideration for an industrial fluid heating application. Your particular process will present its own set of specific temperature sensing challenges with respect to performance and safety. Share your requirements with temperature measurement and control experts, combining your process knowledge with their expertise to develop safe and effective solutions.